Specifications
AM05 AM04 AM03 AM02 AM01 AM00 Hex Access Type
1 0 1 0 0 1 29 A16 non-privileged
1 0 1 0 0 0 2A RFU
1 0 1 0 0 1 2B RFU
1 0 1 1 1 0 2C A16 lock command (LCK)
1 0 1 1 1 1 2D A16 supervisory
1 0 1 1 1 0 2E RFU
1 0 1 1 1 1 2F Control/Status register
1 1 0 0 0 0 30 RFU
1 1 0 0 0 1 31 RFU
1 1 0 0 1 0 32 A24 lock command (LCK)
1 1 0 0 1 1 33 RFU
1 1 0 1 0 0 34 RFU
1 1 0 1 0 1 35 RFU
1 1 0 1 1 0 36 RFU
1 1 0 1 1 1 37 RFU
1 1 1 0 0 0 38 A24 non-privileged 64-bit MBLT
1 1 1 0 0 1 39 A24 non-privileged data
1 1 1 0 1 0 3A A24 non-privileged program
1 1 1 0 1 1 3B A24 non-privileged BLT
1 1 1 1 0 0 3C A24 supervisory 64-bit MBLT
1 1 1 1 0 1 3D A24 supervisory data
1 1 1 1 1 0 3E A24 supervisory program
1 1 1 1 1 1 3F A24 supervisory BLT
Table 5-2 VME Address Modifier Codes (Continued)
5.4.2 VME Address Capture Control Register (Write Only)
765 43 2 1 0
|________|________|_________|________|_________|_________|_________|_________|
||| || | | |
RFU RFU RFU RFU RFU ABORT RESET ENABLE
CAPTURE READ CAPTURE
SEQUENCE
Bit 0: Enable Capture
0 = no action
1 = enable capture for a subsequent VME bus error
NOTE It is recommended that the bus error interrupt is used to give notification of the bus
error event.
Bit 1: Reset Read Sequence
0 = no action
1 = reset captured address read access sequence to entry 1
Bit 2: Abort Capture
0 = no action
1 = Abort Current Capture (following this action all VME address information is invalid)
Bits 7- 3: Reserved
5-6 VP 110/01x
VME Interface