Datasheet
Chemical System: Lithium
Lithium/Iron Disulfide (Li/Fe
S
2)
Designation: ANSI / NEDA-24LF, IEC-FR03
Battery Voltage: 1.5 Volts
Average Weight: 7.8 grams (0.3 oz.)
Volume: 3.8 cubic centimeters (0.2 cubic inch)
Storage Temp: -40ºC to 60ºC (-40ºF to 140ºF)
Operating Temp: -40ºC to 60ºC (-40ºF to 140ºF)
Lithium Content: Approximately 0.5 grams per cell
Jacket: Non-magnetic Plastic Label
Transportation: Meets requirements of 49CFR 173.185 (b)
and IATA special provisions A45.
Shelf Life: 15 years
ENERGIZER NO. L92
Product Availability: Fall 2004
AAA
Contents herein are not an offer for sale.
Industrial Standard Dimensions in mm (inches)
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Eveready Confidential - Not to copied or distributed without written consent from Energizer
Typical Constant Battery Service @21ºC
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
EVEREADY BATTERY CO.
Internet: www.energizer.com
1-800-383-7323 / USA
1-800-383-7323 / CANADA
CONSTANT CURRENT DISCHARGE
500 and 1000 mA Continuous Drain
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Service, Hours
Voltage, CCV
500 mA1000 mA
Typical Temperature Effects on Batteries
Typical Percent Service Maintenance
50
60
70
80
90
100
0246810
Years
Percent Service
0ºC
20ºC
70ºC
40ºC
CONSTANT CURRENT DISCHARGE
100 mA Continuous Drain
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0 2 4 6 8 10 12 14
Service, Hours
Voltage, CCV
100 mA
ENGINEERING DATASHEET
Form No. EBC - 4209D Page 1 of 2