LA Controller
DIP Switch #1 ON (switch position down)
DIP Switch #2 ON (switch position down)
When power is first applied to the LA-Controller without power applied to the YELLOW
ignition wire:
Actuator extension stays where it is at power up.
The wired 3-button switch does not work.
The 3 wires for the optional push button input switches do not work.
With power applied to the YELLOW ignition wire:
Actuator extension moves to preset #2.
All buttons on the wired 3-button switch function normally.
All 3 wires for the optional push button input switches function normally.
Power removed from the YELLOW ignition wire:
Actuator extension moves to preset #1.
The wired 3-button switch does not work.
The 3 wires for the optional push button input switches do not work.
Until power to the LA-Controller is removed, the actuator continues to cycle between preset
#2 and preset #1 as the YELLOW ignition wire is powered and power is removed from the
ignition wire.
Ordering Key: