User guide

Corporate Office: 724.584.5500 Instant Access 24/7 (Parts and Service): 800.458.1960 Parts and Service: 814.437.6861
30
theSetpointdisplayuntilthecorrectpasswordvalueisshown.Toenterthepassword,press
andreleasetheStartbutton.
Ifthepasswordisenteredincorrectly,therewillbea“no”ontheSetpointdisplayand"PAS"on
theActualdisplay.After5seconds,theunitwillgobacktothepasswordentrymodeand
display“PAS”ontheActualdisplayand"blanks"ontheSetpointdisplay.Ifnoactivity occursfor
another5seconds,thecontrollerexitstheprogrammingmodeandreturnstotheStopped
state.
Onceintheprogrammenu,usetheDisplay/Programbuttontoscrollthroughthedifferent
adjustableparameterasshowninTable4onthenextpage.Tochangeanitem,pressthe
Display/ProgrambuttonuntiltheitemcodedisplaysintheActualdisplay.PressingtheAlarm
ResetbuttonandDisplay/Programbuttonatthesametimewillreversethedirectionthe
Display/Programbuttonindexesthroughthemenuitems.Oncethedesiredmenuitemcode
displaysintheActualdisplay,usetheUpandDownarrowbuttonstoadjustthevalveshownin
theSetpointdisplayuntilthedesiredvalueisshown.PresstheStartbuttontoenterthedisplay
value.PresstheStopbuttontocanceland
reverttothepreviouslyvalue.
ThereisaMasterResetfunctiontorestoreallUsermenuparameterstotheirfactorydefault
values.ToinitiateaMasterResettheunitmustbeinastoppedstate.Oncetheunitisstopped,
pressandholdtheAlarmSilence/ResetbuttonandStopbutton
simultaneouslyfor10
consecutivesecondsuntil“PRG”isdisplayedontheSetpointdisplayand"RSt"isdisplayedon
theActualdisplay.ToconfirmaMasterResetisdesired,pressandreleasetheStartbuttonand
thesystemwillperformaMasterResetandreboot.TheMasterResetisabortedafterthe
“PRG”isdisplayedontheSetpointdisplayand“RSt”isdisplayedontheActualdisplaybyturn
thecontrolpoweroffortakingnoactionfor10consecutiveseconds.