Specifications
Table Of Contents
- ugh015-0100.pdf
- Contents
- Introduction
- Description
- Installation
- Operation
- Maintenance
- Troubleshooting
- Before beginning
- Diagnostics
- Repair
- Checking and replacing fuses
- Resetting overloads
- Replacing the pump overload
- Replacing the motherboard
- Replacing the heater contactor
- Checking thermocouples
- Replacing thermocouples
- Repairing solenoid valves
- Replacing heater elements
- Removing the pump
- 3/4-2 Hp Pump disassembly/assembly
- 3-7.5 Hp Pump disassembly/assembly
- Appendix
- Parts/Diagrams

UGH015/0100 Thermolator TW-1 and TW-2
TROUBLESHOOTING 6-21
Lift the heating element out of the heater tube.
Lift the element straight up.
Replace the heater gasket if it is worn or cracked.
Use a high termpertaure Teflon paste to ensure a good
seal.
Reverse these steps to install the new heater
element and reassemble the unit.
REPLACING
HEATER
ELEMENTS
Heater cap
Heater element
Heater gasket
8
9
10