Thermolator TW-1 and TW-2 UGH015/0100
4-8 OPERATION
TW-1 and TW-2 direct injection and closed circuit models can
be ordered with an optional purge valve, which clears the
process lines of fluid using compressed air. The valve is oper-
ated by a manual purge switch on the side of the unit.
IMPORTANT: Before purging the process lines, be sure
that the cooling water source feed is closed. If the feed is
open and the air line has a higher pressure than the cooling
water, air may be injected into the cooling water system. If
the cooling water pressure is higher than the air line, cooling
water may be injected into the air line.
Press to shut down the Thermolator.
The RUN/STOP LED turns red.
Turn off the cooling water supply to the unit.
Press and hold the manual purge switch to start
purging.
The Purge Valve LED lights.
The Vent and Cool outputs are activated.
The STOP and RUN buttons are deactivated during the
purge or when the cool delay off timer is active.
The time required to clear the process lines of fluid will
vary according to the length of the process piping and the
size of the tooling.
Release the purge switch to stop purging.
USING THE
MANUAL PURGE
OPTION
Stop
1
2
3
4
NOTE: The purge operation will terminate immediately if
the unit detects a blown fuse in the Vent or Cool output.
The unit will alarm and shut down.
See the T
ROUBLESHOOTING section for instructions on how
to clear the alarm and fix the problem.