wait, and check again until the belt moves straight.
Belt tension.
The conveyor beltÕs length has 1% tolerance. Never tension the beltÕs adjust-
ing screws with a greater tightening torque than 5 Nm.
Maintenance
During all maintenance work on the band conveyor, both the circuit-breaker
and the main circuit-breaker must be ÒOffÓ. Alternatively, the connector must
be pulled out of the power point!
Regularly check the conveyor beltÕs wear and its position on the rollers. The
belt must not move obliquely! Adjust as necessary according to the instruc-
tions under ÒStarting - If the belt moves obliquelyÓ (see previous chapter).
Clean the belt using a light cleaning agent. Do not use any sharp objects,
strong cleaning agents or chemicals which can damage the belt.
Trouble-shooting
If the band conveyor does not start
The conveyor belt motor has an overload circuit
breaker, F3, in the distribution cabinet, which trips
if you jam or overload the conveyor belt.
This is indicated in the window (A) which then
shows an Ò0Ó.
To reset, press the ÒresetÓ button (B).
Also check the wiring diagram in chapter 9, additions
and modifications can occur.
A
B