Specifications

A ppendix l AA-9
Mounting Method 3 (continued)
6 Place the gasket over the probe hole.
7 Place the adapter plates over the gasket and secure
them to the hopper with three 10-32 UNF screws. Make
sure the adapter plate with the threaded holes is on the
bottom, and that the slots in the adapter plates are orient-
ed in the opposite direction as shown. See drawing to
right, #7.
8 Secure the coupling to the adapter plates with the four
10-32 UNF screws.
9 Screw the fitting into the coupling.
Tighten with a wrench.
10 Make sure the probe is the correct size.
The probe should extend from just above the
top of the hopper into the hopper, with the
tip approximately in-line with the bottom
edge of the diffuser cone.
11 Push the compression sleeve into the fitting.
12 Tighten the nut over the sleeve. The compression
sleeve will crimp the tube to hold the probe in place. Be
sure to position the connector in such a way as to avoid
interference of the cable with the loader, etc. Use a
wrench to tighten the nut so that it covers the threads.
9
Gasket
6
Sleeve
Connector
Coupling
Hopper
Nut
Fitting
Adapter
plate
Threaded
adapter plate
7
8
11
12
10