Specifications
Problem
Drying Monitor RTD
Integrity Alarm - This alarm
indicates that one or more of
the RTD sensors within the
Drying Monitor probe have
failed. The drying monitor will
continue to function as long as
the RTD that has failed is not
the one selected for the Low
Alarm or High Alarm RTD, but
the alarm will be present until
the cause of the alarm has been
corrected.
Possible cause
The cable that runs between the Drying
Monitor control and Drying Monitor
probe is loose or damaged.
The cable extending from the dryer con-
trol is damaged, or the wire connections
from this cable to the analog option
board are loose or broken.
Damaged connector on the Drying
Monitor probe.
Defective RTD sensor in Drying
Monitor probe.
Solution
Verify the cable connections are secure.
Repair or replace the damaged cable or
connectors.
Repair or replace the damaged cable or
connectors, or tighten the wire connec-
tions at the analog option board.
Repair or replace the damaged connec-
tor.
Replace the probe.
Passive Alarms
AA-34 l Appendix