User guide
Operation l 4-43
4
Operation
Using the IO Page
Debounce (continued)
The cutter portion has two inputs with adjustable filters. These are End Sense
(used by Product mode) and Good/Bad. Debounce filters are measured in seconds
to three decimal places. When relay or switch contacts are used these should be
filtered between 0.005 and 0.100 seconds. When the signal input is from a transis-
tor or solid-state driver set the debounce amount to zero.
To adjust End Sense or Good/Bad input time filter Debounce time:
1
Press the End Sense or Good/Bad Debounce window. A numeric pop-up
keyboard appears.
2
Key in the new End Sense or Good/Bad input Debounce time duration.
3
Then press “Enter”. The pop-up keyboard is removed.
4
The new End Sense or Good/Bad input Debounce time amount will
appear in the End Sense or Good/Bad input Debounce window and will
then be active.