User guide

Configuring the Batch Settings
(continued) (Optional)
Pulse/Latch
The “Pulse/Latch” button option offers the choice of making the output pulse or
latch on (stay on). The Latch option turns on the output, which will stay on until
the “Reset” button is pressed. The Pulse option will only pulse the output, which
will not require the “Reset” button to be pressed. In the Latch Mode there is an
extra light that is shown on the touch panel to show the state of the Batch
Complete output. The Warn output is automatically cleared when the Batch is
complete.
Pressing the “Pulse/Latch” button will toggle between the Latch and Pulse func-
tions.
Alarm
The alarm function is used as a local alarm only. If a physical Batch Alarm output
is required the Warn or Latch options with outputs at the drive should be used. A
yellow batch complete light is shown as the Batch count reaches the Batch set-
point. The alarm feature has to be enabled in order to operate. “Reset” is then
used to clear the alarm. Pressing
“Reset” also clears a Latched Batch output.
4-28 l Operation