User guide

Configuring the Blow Off Settings
(continued) (Optional)
Style
Pressing the “Style” button will toggle through three different Blow Settings.
Blow Amount as shown in the example above is one of the options. Other options
are "Blow always when Good", or "Blow always when Bad”.
“Blow always when Good” - the Take Off/Blow Off Conveyor’s air will remain
energized (blowing) while the product is good, allowing product to be diverted
sideways off the conveyor. When the product is bad the valve will turn off so the
product will fall off the conveyor into a receptical. The Offset value is used
to delay the valve on or off times.
“Blow always when Bad” - the Take Off/Blow Off Conveyor’s air will remain
energized (blowing) while the product is bad, allowing product to be diverted
sideways off the conveyor. When the product is good the valve will turn off so
the product will fall off the conveyor into a receptical. The Offset value is used
to delay the valve on or off times.
The quality input (good or bad) is used to control the air valve(s). No matter
which option is selected the air valve will always be off when the cutter is
stopped.
See Operation Section entitled, Quality Page Description.
Quality - Good and Bad Indicators
Gauge (Product Quality) Indicator - displays the quality of the product at the
gauge. It will illuminate green if the product is good and red if the product is
bad.
Cutter (Product Quality) Indicator - displays the quality of the product at the
cutter. It will illuminate green if the product is good and red if the product is
bad.
4-24 l Operation
IMPORTANT: The options “Blow
always when Good” and “Blow
always when Bad” can expend a lot
of air. Their settings should be kept
low or not used when possible.