User guide

Installation l 3-17
3
Installation
Testing the Installation
Two-Line HMI Interface Operation
1 Plug in the main power cord and turn on the main disconnect. The display
should fully illuminate and start up. Power on lights will illuminate.
2 Check that the “Emergency Stop” buttons are in the out, extended posi-
tion.
3 Make sure that the Cut On/Off switch is Off. If necessary, press button to
display off.
4 Press “Start Puller” button. The puller must be activated before the cutter
portion can be turned on. Once the puller is running press the start button for
the cutter section, the blade will begin to rotate.
5 Open the knife guard. The machine start push button should go out.
If the cutter is not working properly at any time, turn it off immediately and refer
to the Troubleshooting section of this User Guide.
If you do not encounter any problems, proceed to the Operation section.
NOTE: For more information about setting and adjusting the gap for the bushings,
see
Appendix C, About Cutter Bushings.
0
NOTE: If the “Emergency Stop” button is pushed in, there will be no power applied to the amplifi-
er and the operator interface will display “starting commands” for an extended period of time.
0
(continued)