User guide
Operation l 4-171
4
Operation
Powering Up the Cutter
1 Plug in the power cord to restore power after any required maintenance.
2 Turn on the main power. The cutter control will start up. The amber power on
light illuminates. (Two line HMI only)
While the cutter is booting up, perform the next three steps:
3 Make sure the “Emergency Stop” button is in the out, extended position.
4 Make sure that the Cut Enable is Off.
If necessary, press button to display off.
5 Press “Start Cutter” button. The cutter head will make one revolution until it
finds its home offset position.
6 Open the knife guard. The light in the push button will go out or the cutter
status on the Main Page will show “Stopped” in red.
If the cutter is not working properly at any time, turn it off immediately and refer
to the Troubleshooting section of this User Guide.
If you do not encounter any problems, proceed to the Operation section.
Programming the Puller Speed
After powering up the combination puller/cutter, you need to set the puller speed.
See Operation Section entitled, Setting Puller Speed and Puller Operator
Instructions, Operator Entered Speed Change and Using Scroll Increments.
NOTE: You can watch the servo motor amplifier's status screen during start up through
the window on the back of the electrical enclosure. This display gives information that
may be useful if you have a problem. See the
Troubleshooting section
of this manual.
0
NOTE: If “Home Runtime Failed” message is displayed or if you receive a “Home Failed
(Sensor may be damaged” on the Faults Page on the touch panel HMI. Check for mal-
functions of misadjusted sensor.
0
NOTE:
See Operation Section
entitled, Angles Page
Description
for steps to cut and
park angles if using Red Lion HMI
and Control Techniques/
Emerson Servo Drives
0