Puller Operator Control Instructions:
Diagnostics Screen
There are three servo puller control system diagnostics screen. Refer to the Servo
Drive and Amplifier manuals which came with your belt puller to service your system.
The servo amplifier will have a window with letters or numbers to represent opera-
tional conditions.
To acknowledge and clear a fault:
1
Correct the fault. There are three servo system diagnostic screen displays:
001 - Drive Fault, 002 - Drive Torque Limit Exceeded, 003 - Communication
Failure.
Reference the Servo Drive and Amplifier manuals that came with the
puller for specific causes and solutions for each fault.
2
Acknowledge the fault or faults, by pressing the “Accept” or “All” Softkey.
Specific faults can be acknowledge by pressing the softkey directly under the word
“Accept”. Multiple faults can be acknowledged by pressing the softkey directly
under the word “All”.
3
The control display will return to the Main Screen after the fault has been
corrected and acknowledged.
003 COMMS FAILURE
ACCEPT ALL
NOTE: If the fault is not acknowledged, even if the fault was corrected, the display will
not return to the Main Screen.