User guide

Puller Operator Control Instructions:
Programming Scroll Increments
The Scroll Increment Screen provides programmable preset scroll increments for
puller speed. Increments are set for course (Lg), fine (Sm) and remote (Rm) scroll
adjustments.
To adjust scroll increments:
1
Press the “Menu” button.
2
Key in the new Course (Lg.) increment preset using the numeric keypad.
When accessing this screen the cursor will always start at the Course (Lg) least
significant decimal point. For example, to change the Lg scroll increment to 5 feet
per minute, enter “5 0”.
3
Use the “Enter” button or the “Next” and “Prev” buttons to move to other
scroll increment presets. The least significant decimal point will be highlighted
when moving between scroll increment presets. After entering the new remote
(Rm) preset, pressing the “Enter” button will exit this page and return the operator
to the Main Screen.
4
Press the “Exit” button from any point in the Scroll Increment Screen to
return to the Main Screen.
Value Ranges for Scroll increments:
Lg (Course) = 0-99.9 feet per minute per contact (Default = 10.0)
Sm (Fine) = 0-9.9 feet per minute per contact (Default = 1.0)
Rm (Remote Pot) = 0-99.9 feet per minute per contact (Default = 5.0)
Enter Inc/Dec Values
Lg 10.0 Sm 1.0 Rm 5.0
4-162 l Operation