User guide

4-152 l Operation
Cutter Control Instructions: Scale
Distance
DISTANCE SOFTKEY
By pressing the soft key located under the word Dist. on the Scale Value Screen,
the scaled distance is available. This value must be set after a U/M change.
Additional information on how to access this screen can be found in the
Maintenance Area of the operator display overview in Appendix G of this manual.
The number shown is the current distance value, i.e. the circumference of the
measuring wheel or distance per revolution of the encoder. A cursor will appear in
the least significant digit.
Exit or Prev- if no change is required press Exit or Prev to return to the Scale
Value screen.
Raise will increase the value by 0.001inch. The key can be pressed once for each
0.001inch increment required or held down to scroll up. Releasing the key will
freeze the value at the last value.
Lower will decrease the value by 0.001inch. The key can be pressed once for each
0.001inch decrement required or held down to scroll down. Releasing the key will
freeze the value at the last value.
Numeric keys
Key in the distance desired and press enter. The decimal place is fixed so remem-
ber this when entering the value. If you require 12.000 inches you must key in
12000 and then press enter. Keying only 12 will set the distance to 0.012 inches.
Enter or Delete?
If the keyed in number is correct press the enter key for it to be accepted and return
to the Scale Value screen. If it is wrong press the delete key and the previous value
will reappear.