User guide

Operation l 4-145
Cutter Control Instructions: Test
Next, Pressing Next selects the DevCC test if available. If the arrow on the top
right hand side of the screen is visible the current mode also supports the DevCC
test.
The DevCC repeatability tester also displays total deviation time in milliseconds.
This time is from a cut being requested until the next cut request. The smallest
measured value is subtracted from the largest measured value and the resulting
deviation is displayed on the screen. The DevCC repeatability test is available in
some on-demand modes, and all continuous modes. This test is used as a tool for
verifying the accuracy of the upstream puller or the precision timer option.
On/Off Softkey1
On the display, on the lower left side is a soft key labeled On or Off. Pressing this
key while On is displayed will reset all values and disable testing. Likewise press-
ing this key while Off is displayed starts the test.
Reset Softkey3
On the display, on the lower right side is a soft key labeled Reset. Pressing this key
will reset all test values and start a new test.
Exit, Pressing Exit or the Softkey under the word Exit resets all values, disables
testing then returns the display to the Function area screen.
Prev, Pressing Prev selects the DevCP test if available. If the arrow on the top left
hand side of the screen is visible the current mode also supports the DevCP test.
4
Operation
(continued)
NOTE: The test available DevCP, DevCC or both is dependent on the active cut mode
.
0
NOTE: The test available DevCP, DevCC or both is dependent on the active cut mode.
0