User guide

4-124 l Operation
Profile/Bubble/Taper Mode -
Digital Outputs Page Description
Digital Outputs are available in groups of four; 4, 8, 12 and 16 digital outputs are
possible. A PLC (Programmable Logic Controller) or PLC's provide the digital out-
puts.
Four digital outputs are shown in this example. A digital output can be on or off.
These are typically used to operate pneumatic valves. The digital graph is shown
under the profile graph. The waveform shows what will happen while the puller runs.
To access the Profile/Bubble/Taper Digital Output Sub-Page:
1
Press the Set Up 1 tab and then press the Modes sub tab.
2
Select Profile/Bubble/Taper Mode for both the cutter and puller sections.
“Profile” will be displayed at the bottom of each section when properly selected.
3
Press the Main tab.
4
A “Profile Settings” button will now be displayed in the cutter portion’s
length window.
5
Press the “Profile Settings” button to access the Profile/Bubble/Taper
Main Page.
6
Press the Digital Outputs tab to access the Profile/Bubble/Taper Digital
Outputs Sub-Page.