User guide

Profile/Bubble/Taper Mode -
Velocity Page Description
(continued)
Drive Data
The drive receives the information that the operator enters into the Combination
Puller/Cutter, but in a different format
. A pop-up is shown after pressing the “Check
Drive Data” button from the Velocity Page. The button, when pressed, shows a list of
values that are downloaded into the drive. This list is primarily for diagnostic purpos-
es, which the operator can ignore.
To access the Drive Data list:
1 Press the “Drive Data” button.
2 Press the “Exit” button to remove the Drive Data list.
Drive Data is formulated as follows:
Velocity = Final Velocity
Length = Ramp Length + Level Length
Ramp = absolute
(Final Velocity - Initial Velocity) x (Final Velocity + Initial Velocity)
2 x Ramp Length
(
)
4-114 l Operation