User guide
Operation l 4-97
4
Operation
Cuff Page Description (continued)
Gate Off Distance
Gate Off Distance is used to disable the sensor for the length set once a cuff has
been detected. The length set should be less than the actual distance between cuff
sections, this is so the Trigger Distance setting sensor will be active to detect the
next cuff. Set lengths of 80 to 90% of the length between cuffs should be used.
To set the Gate Off Distance:
1 Press the Gate Off Distance window. A pop-up keyboard appears.
2 Press “Enter”. The pop-up keyboard is removed. The new Gate Off Distance
will now be displayed.