User guide

Operation l 4-63
4
Operation
Ramps Page Description
Puller (continued)
To change the Puller Ramp type:
1
Press either the Linear, 1/4 S-Curve, 5/8 S-Curve or S-Curve radio button.
A dot will appear in the radio button of the selected curve type.
Acceleration and Deceleration preset is the average rate of change that will
be used for speed changes. For example, a puller set to 100 FPM will acceler-
ate from zero in one second with a 100.0 FPM/S ramp.
Stop Deceleration setting of the puller is dependent upon they type of puller
used. Stop deceleration is used to provide a quicker stop as a result of the
“Puller Stop” button being pressed. The stop rate should be set larger
than the normal ramp.
Calculations
Included at the lower portion of the page are sets of calculations. These have no
effect on operation. They serve to provide information only.
NOTE: All values can be
changed by pressing individual
windows and using the key-
board method to alter the value.
See Setting the Cutter Length,
Keyboard Method.
0