User guide

Ramps Page Description
Cutter (continued)
Linear - rate of change is constant throughout the speed change
1/4 S-Curve - linear portion is 1.143 x average acceleration
5/8 S-Curve - linear portion is 1.455 x average acceleration
S-Curve - linear portion is 2 x average acceleration
To change the Cutter Ramp type:
1
Press either the Linear, 1/4 S-Curve, 5/8 S-Curve or S-Curve radio button.
A dot will appear in the radio button of the selected curve type.
Acceleration and Deceleration setting is the rate of speed the cutter arm will
take to achieve running speed or to slow down to a complete stop. The cutter’s
acceleration and deceleration rate is dependent upon the type of cutter arm
being used.
Stop Deceleration setting of the cutter is dependent upon they type of cutter
arm being used. Stop deceleration is used to provide a quicker stop as a result
of the “Cutter Stop” button being pressed. The stop rate should be set larger
than the normal ramp.
Operation l 4-61
4
Operation
NOTE: All values can be
changed by pressing individual
windows and using the key-
board method to alter the value.
See Setting the Cutter Length,
Keyboard Method.
0