User guide
Ramps Page Description
Cutter (continued)
• Linear - rate of change is constant throughout the speed change
• 1/4 S-Curve - linear portion is 1.143 x average acceleration
• 5/8 S-Curve - linear portion is 1.455 x average acceleration
• S-Curve - linear portion is 2 x average acceleration
To change the Cutter Ramp type:
1
Press either the Linear, 1/4 S-Curve, 5/8 S-Curve or S-Curve radio button.
A dot will appear in the radio button of the selected curve type.
• Acceleration and Deceleration setting is the rate of speed the cutter arm will
take to achieve running speed or to slow down to a complete stop. The cutter’s
acceleration and deceleration rate is dependent upon the type of cutter arm
being used.
• Stop Deceleration setting of the cutter is dependent upon they type of cutter
arm being used. Stop deceleration is used to provide a quicker stop as a result
of the “Cutter Stop” button being pressed. The stop rate should be set larger
than the normal ramp.
Operation l 4-61
4
Operation
NOTE: All values can be
changed by pressing individual
windows and using the key-
board method to alter the value.
See Setting the Cutter Length,
Keyboard Method.
0