User guide

Scroll Page Descriptions (continued)
Puller Scrolls - Remote Digital Pot
Two settings are available for remote digital pot. One is used for Speed Modes
such as Master. A click clockwise or counterclockwise made by rotating the digi-
tal potentiometer will add or subtract this increment to the speed setpoint on the
Main Page.
To change the Speed Modes scroll increment:
1 Press the Speed Modes FPM window. A numeric pop-up keyboard appears.
2 Key in the new scroll increment. Lower product line speeds will require a
smaller increment change, higher product line speeds will require a larger
increment change. Also, this number is dependent on the number of rotations
of the remote digital potentiometer’s rotary dial. For fewer rotations set a
courser number, for more rotations set a finer number.
3 Then press “Enter”. The pop-up keyboard is removed.
4 The new scroll increment will appear in the Speed Modes window and will
then be available.
NOTE: Remote Digital Pot scroll increments are dependent on the type of product that
is produced and user preference.
0
4-58 l Operation
(continued)