User guide

Weekly
Cleaning the blade lubrication tray
(See Cleaning the Blade Tray, Section 5).
Lubricating shafts on optional slide rail system
(See Lubricating the Slide Rail System, Section 5).
Monthly
Checking hardware on the knife guard
Inspect the hardware on the knife guard (fasteners on
hinge and the clear blade guard window). Tighten as
needed.
Checking bushing holder proximity switches
Inspect the sets screws which retain the bushing holder
proximity switches for tightness. Adjust as needed.
(See Adjusting the Proximity Switches, Section 5).
Checking the metal draw latch
Inspect the latch on knife guard for wear and proper
tension. Readjust or replace as needed.
PREVENTATIVE
MAINTENANCE
SCHEDULE
C
ONTINUED
UGE047/1003 CSC Servo Knife Cutters
MAINTENANCE 5-5
Clean the clear blade guard window
Clean using glass cleaner or plain water. Other materi-
als may cause premature loss of clarity or crazing.
Semi-annual (every 6 months)
Inspecting electrical terminals
Check all electrical terminals for tightness; adjust as
needed. (See Checking Electrical Connections, Section
5).
Checking torque on Trantorque coupling device
Check the tightness (torque) of the Trantorque coupling
device with a torque gauge. This device connects the
cutter head to the Micron reducer shaft. (See Checking
Torque, Section 5).
Checking all electrical cables
Inspect all electrical cables for cuts and abrasions.
Replace as needed.
Inspecting control panel lights
Check to make sure no LEDs or lights are burned out
on the control panel. Replace as needed.