11 Specications
11.1 Technical Data
Condair GS 40 80 120 160 200 240
Steamoutput
room air-dependent kg/h 10…40 10…80 10…120 10…160 10…200 10…240
room air-independent (RS units) kg/h 10…40 10…80 10…120 10…160 10…200 10…240
Energyconsumption kw 36.5 73.0 109.5 146.0 182.5 219.0
Gasous fuel Natural gas (G20, G25, G25.1, G27, GZ350) or Propane gas (G31)
Electric connections
powersupply 230V/50…60Hz/1Phase
powerconsumption W 460 690 920 1150 1380 1610
powersupplyfuse 10A,slowacting
Mechanical Connections
Fillwaterinlet Inch BSP3/4"
Drain Inch 3/4" (19 mm)
Auxiliarydrain Inch NPT 1/2"
Gas line Inch BSP1/2" BSP3/4" BSP1" BSP1" BSP11/4" BSP11/4"
Steam hose connection Inches 1 3/4" (45 mm) 3" (76 mm) 3" (76 mm) 4" (101 mm) 4" (101 mm) 4" (101 mm)
Flue pipe connection Inches 3" (76 mm) 4" (101 mm) 5" (127 mm) 5" (127 mm) 6" (152 mm) 6" (152 mm)
Humiditycontrol
Possible control signals 0…5VDC / 1…5VDC / 0…10VDC / 0…20mA / 4…20mA
Dimensions
Height cm 81 (158 unit on stand)
Width cm 114
Depth cm 53 69 109 109 149 149
Shipping weight kg 174 210 295 319 358 382
Operating weight
lled kg 211 273 459 471 610 623
empty kg 140 162 238 261 290 314
Operating conditions
Admissiblewaterpressure bar 3…8
Water quality untreateddrinkingwaterorfullydemineralizedwater
Admissible gas supply pressure mbar G20: 17…25 / G25: 20...30 / G25.1: 20...30
G27: 17.5…23 / GZ350: 10.5...16 / G31: 25...57.5
Admissible ambient temperature 5…30
Overpressureattheueoutlet
at full load
at minimum load
Pa
Pa
80
5
Type of protection IP20
Admissible duct air pressure Pa –800 ... +1700
Furtherinformations
Conformity CE
Patents Condair®internationaltrademark/internationalpatents