Specifications
63
Replacingthetransformer
1. Takethehumidieroutofoperation,asdescribedinchapter7.5.
2. Undothescrew(phillipsscrewdriver)andremovetherightfrontpanel.
3. Remove the connection cables to the transformer, if necessary labeling the cables before removal.
4. Unscrewthetwonutsandremovehetransformer.
Re-installationiscarriedout inthereversesequence. Make surethecablesare connected cor-
rectly.
Replacingthedrainpump
1. Takethehumidieroutofoperation,asdescribedinchapter7.5.
Important!Ifdrainpumpisdefective,draintankmanuallyviatheauxiliarydrain.
2. Undothescrew(phillipsscrewdriver)andremovetherightsidepanel.
3. Remove the connection cables to the drain pump (note assignment before removal).
4. Remove hose clamps on the drain pump connections and pull off the hoses, then remove the
drain pump.
Re-installationiscarriedoutinthereversesequence.Makesurethehosesarecorrectlysecured
withthehoseclampsandthecablesareconnectedcorrectly.