Specifications
55
8 Maintenance
Qualicationofpersonnel
Allmaintenanceworkmustbecarriedoutonlybywellqualiedandtrainedpersonnelauthorised
by the owner.
Maintenance and repair of the electrical installation of the Cond air GS must be carried out only by
qualiedpersonnel(e.g.electrician)beingawareofpossibledangerandimplications.
Itistheowner’sresponsibilitytoverifyproperqualicationofthepersonnel.
General notes
Theinstructionsanddetailsformaintenanceworkmustbefollowedandupheld.
Onlythemaintenanceworkdescribedinthisdocumentationmaybecarriedout.
Only use original Condair spare parts to replace faulty parts.
Safety
Beforemaintenanceisinitiated,theCondairGSmustbetakenoutofoperationinaccordance
with instructions in chapter 7.5 and protected against unintentional switching on.
8.2 Maintenance instructions
To maintain operating reliability, the Condair GS mustbeservicedatregularintervals. Here, a
distinctionismadebetweentherstserviceafter500hoursofoperation(I), theminorservice
everytimethemaintenancealarmappears(II) and the annualmaintenance(III).
Important!Dependingonthehardnessofthewaterandtheaveragesteamoutput,undercertain
circumstancesitmaybenecessarytoreducetheserviceintervalfortheminormaintenancework.
If the limeresiduesdepositedontheoorofthetankexceedaheightof5cm the interval must
bereduced.Iftheheightislessthan5cmtheintervalcanbeextended.
Important: Every service action must be documented in the “Maintenance” report sheet (a copy of
this document is provided in these installation, commissioning and service instructions). Warranty
isvoidifthespeciedmaintenanceintervalsarenotobservedandthemaintenanceworkarenot
carried out according the instructions.
Thefollowingisanoverviewoftheworktobecarriedoutateachoftheservicestages.
Components Interval Workrequired
I II III
Watertank X X X Drainthetank,thenopenitandmeasuretheheightofthe
limeresiduesonthetankoor(max.5cm).Removethe
limefromthetank.
Checkallpipeconnectionstothetank(speciallythelevel
unit passages). Clean if necessary.
Water outlet pipes, including
siphon
X X X Pressthedrainswitchandcheckforfreedrainage.
Inspect all pipes for lime deposits and for correct sealing.
Cleanorreplacepipeswithlimedeposits.Reseal/replace
leakingpipes.
8.1 Importantnotesonmaintenance