User guide

TrueFeed manual
28
7.8 Auto / Manual regulation mode & save data function
Two functions are available within one screen:
- Regulation mode: Auto/Manual
- Save data function.
These two functions are not accessible within the OPERATOR user level.
Regulation mode: Auto/Manual
This function allows you to switch from automatic control (gravimetric) to manual control (RPM) during
operation. It is only accessible when the TrueFeed’s motor is on and the control is not in the Operator
user level.
In this screen the RPM can be changed.
-When changing back to Auto mode without saving data, the unit will revert to the “old” RPM and continue
self-calibrating.
-When changing back to Auto mode after saving data (manual entered speed), the unit will first keep the
manual set speed but will self-calibrate to the entered setpoint.
Save data Function
This selection allows storing the actual data once the feeder shows an actual value (color actual). A material
description needs to be entered to save this data. A full material curve based on the stored point will be saved
in the memory of the control under the entered name.
Starting a new production run with a previously stored material calibration/speed is now possible.
PRODUCTION
Regulation mode
Auto/Manual
Save data: YES/NO
PRODUCTION
Regulation mode
Manual
Man Speed: xxx.x rpm
Save data: NO/YES
Weight : xxxx gr.
PRODUCTION
Regulation mode
Auto/Manual
Save data: YES/NO
PRODUCTION
Fill in material
Description: XXXXXXXX
Manual Æ ENTER
Save data Æ YES