7.5 Load cell calibration
Two types of calibrations are available for the TrueFeed, depending on the selection made in
CONFIGURATIONS:
1. Automatic - The advantage of automatic calibration over manual calibration is that the automatic
calibration is self-calibrating and the probability of failures will be reduced. Also, the accuracy is higher
with changes of output because a complete material curve will be produced.
2. Manual - Running in RPM mode (external scale is required)
When using a TrueFeed for the first time, a load cell calibration must be performed:
• The unit must be mounted horizontally (water leveled)
• Avoid vibrations during the load cell calibration. This will effect the calibration.
• Do not touch the unit during load cell calibration.
• When using an optional slide frame the unit must be slid in against the throat adaptor and secured.
• Be sure that the load cell is connected to the control
• Navigate to the LOAD CELL menu
• In this menu it is possible to calibrate the load cell of TrueFeed
(a 1.1 lb {500 g}. calibration weight is required)
• Select “YES” to start the load cell calibration
[***] = Progress
• After a few minutes the following screen appears:
Place the calibration weight (1.1 lb {500 g}) on the hopper
and press the “START” button.
• After approximately one (1) minute the load cell calibration will be complete, press the “MENU” button to
continue.
• To check if the load cell calibration was correct, navigate to the WEIGHT CHECK menu.
LOADCELL CALIBRATION
[***]
Status
Calibration busy.
Please wait…………..
LOADCELL CALIBRATION
[***]
Status
Place weight, press
START when ready.