User guide

TrueFeed manual
15
7.4 CONFIGURATIONS
For the initial setup of the TrueFeed, the control must be configured from the CONFIGURATIONS menu.
Depending on the CONFIGURATIONS, some settings will be removed because they are not relevant.
Highlighted Parameters are factory settings.
Language : ENG / SP
Motor type : LT / HT
Cylinder type : GX / GLX / HX / A20 / A30 (for A15 select GX cylinder type)
Material type : NORMAL / MICRO
Cal dev. : 5.0 %
Control mode : GRAVI / RPM
Prod. Mode : INJ / EXT
Input mode : Timer / Relay / Tachometer
Input filter : (1 -32)
Fill. System : NO / ME / MV / EX
EX HH level : 3500 g. (7.7 lb)
EX H level : 2500 g. (5.5 lb)
Filling start : 800 g. (1.7 lb)
Hopper empty : 700 g. (1.5 lb)
Deviation alarm : 25 %
Jobs enabled : NO / YES
Auto start : NO / YES
Master reset : NONE / ALARM / MATER / JOBS / ALL
IP : xxx . xxx . xxx . xxx (For example: 192.168.001.001)
Name : xxxxxxxxxxxxxx
Start user : Operator / Tooling / Supervisor
Tooling passw. : xxxx 1111
Supervisor passw. : xxxx 2222
Conversion : Metric / Imp / kg/h
Full scale : xx.xx kg
Modbus unit : 1 - 231
Date : (dd / mm / yy)
Time : (hh / mm / ss)
CONFIGURATIONS: Language
Standard language is English. Alternate languages are available upon request.
CONFIGURATIONS: Motor type
LT is Low Torque motor and HT is High Torque motor (See Chapter 5 for more information)
Do not select HT motor if a LT motor is installed.
CONFIGURATIONS: Cylinder type
Type of dispensing cylinder / feed auger (See Chapter 5 for more information)
CONFIGURATIONS: Material type
Type of material: normal granules (NORMAL) and micro-granules (MICRO).
(see chapter 5 for more information)
CONFIGURATIONS: Cal dev.
The maximum allowed deviation from the Calibration Setpoint can be set with this
parameter. (See Chapter 7.6 for more information)