User guide

TrueFeed manual
13
7.2 Start up and login
Immediately after turning on the main power to the TrueFeed, the software versions will be displayed. In the
first screen the software version of the terminal will be shown.
After a few seconds the second screen appears for 10 seconds.
Vx.x = User software version Vx.x
SP-Vx.x = Language version Vx.x
(Standard language is English)
(SP means that the additional language is Spanish)
BL Vx.x = Bootloader software (firmware) Vx.x
Mac address = ID address of the network card
The TrueFeed control has three (3) user levels:
1. Operator 2. Tooling (Supervisor – level 1) 3. Supervisor (Service – level 2)
The functions which are accessible per user level are shown in the table below.
The Operator level is the lowest level, only the settings for production can be changed. The rest of the settings
/ menus are removed or locked.
To access a different user level, navigate to the LOGIN menu and enter the corresponding password (4
numerals) and press “Enter”. The passwords for the Tooling and Supervisor user levels can be defined by the
supervisor in the CONFIGURATIONS menu.
USER LEVEL
Can be changed in LOGIN menu.
MENU TITLE: FUNCTION:
SUPERVISOR
Default code
2222
TOOLING
Default code
1111
OPERATOR
Default code
0000
[LOGIN] To enter the different user levels.
YES YES YES
[CONFIGURATIONS] To configure the feeding system.
YES NO NO
[PRODUCTION] To adjust the production settings.
*In OPERATOR level jobs and materials are read-only.
YES YES YES*
[FILES] To look for, rename or delete jobs and curves.
YES NO NO
[HOPPER LOADER] To adjust the hopper loader settings,
only visible when a hopper loader is selected.
YES YES YES
[CALIBRATION] To make material calibrations, only visible when control
mode is set to GRAVI (Gravimetric).
YES YES NO
[LOAD CELL] To calibrate the load cell.
YES NO NO
[WEIGHT CHECK] To check the hopper or object weight.
YES YES NO
[CONSUMPTION] Viewing of the total quantity of material dosed by the
TrueFeed.
YES YES NO
[ALARMS] Viewing of the alarm history
*In TOOLING level the alarm CONFIGURATIONS is
removed.
YES YES* NO
[EVENT LOG] The history of events or settings will be logged in this
menu.
YES NO NO
Recommended to note the passwords
If you forgot your supervisor password, contact Conair Service 1-800-458-1960.
If the wrong password has been entered, the user level will automatically be set to Operator level.
Conair Terminal
Version x.xx
Date: January 2005
Conair TrueFeed
Color in Control
Vx.x
SP-Vx.x
MENU to continue
BL Vx.x
Mac-00:12:EC:xx:xx:xx