User guide

TrueFeed manual
9
6.4 Changing from dispensing cylinder to feed screw
In relation to the maximum capacity of the dispensing cylinder, it may be necessary to change from the
selected dispensing cylinder to a feed auger. The feed auger system consists of a rotating auger in a non
-
rotating tube.
To install the feed auger:
1. Detach the motor quick release clamps and remove the motor from the hopper.
2. Dismount the throat adaptor connection flange (1) by removing the four socket-head screws.
3. When using a dispensing cylinder, the throat adaptor connection flange (1) is equipped with a ball bearing
(5). When using an auger screw system the ball bearing must be removed. The metal ring (2) which is fixed
on the feed screw tube fits directly on the throat adaptor connection flange.
4. Remove the dispensing cylinder (3) and mount the screw (4) with the M5 bolt.
5. Replace the motor and auger by closing the motor quick release clamps.
The motor and auger can be easily removed for cleaning.
POSSIBLE COMBINATIONS
1
3
4
2
Art.nr:H000011
Included ball bearing
Art.nr:H000002
GX / GLX / HX
A15/ 20 / 30
5