Technical information
– INTRODUCTION –
– INFRANOR
V
ariable–Speed Drive –
21/04/95
01T00357
6
Page
2 – Vertical
Load Configuration
2 – 1.Operating Principle
.
In order to of
fset the downward movement of the arm before it is raised,
a vertical load compensation must be implemented.
. This compensation adds a current offset which may be positive or
negative depending on mechanical configuration.
. The required option is selected using a strap.
. The offset value is defined by resistor R120 = 80K
Offset
direction
Load
Strap
+12v
–12v
–
+
R120
(80K)
Current set point