Technical information

– INTRODUCTION –
– INFRANOR
V
ariable–Speed Drive –
21/04/95
01T00357
3
Page
II – IMPLEMENT
ATION
1 – Pr
eliminary Checks
Follow the procedure described below using the axis identification sheet and
bearing in mind the maximum speed requirement:
– Enter the list of parameters.
– Check the configuration of the variable–speed drive as follows:
. Integral gain: strap or capacitor set to PAV–D
. Number of encoding points: switch A14 set to ON or OFF
. Vertical compensation strap: 2 directions possible if present
Check that the fastening screws on the front panel of axis modules are tightened.
This is to ensure that the shielding required to protect the equipment against
interference is uninterrupted.
2 – Power–up
– Close the main isolating switch of the cabinet
– Check the main and auxiliary power supplies: 220V AC (240V AC max)
– The power is not set,
the display on the front panel should indicate a fault as follows:
– Reset the power. The display is now:
if the display is not as shown, refer to the section entitled “Safety Devices Stored
in Memory” in the Maintenance chapter in the description manual.