User guide

Operation
TrueBlend
90 Edition: February 2008
Î Open the “quick-release” locks of the
mixing chamber end cover and remove
it.
WARNING!
DANGER OF INJURY!
After extended operation the edges of the mixing blades can be knife-sharp
and may cause injuries by cutting.
Î Wear gloves when touching or cleaning the stationary mixer.
Cleaning the mixer
Î Once the material compartment has
been cleaned, remove the deflector
Î You will now proceed to clean the mixing
chamber and shut off valve at the bottom
of the chamber.
Î To fully evacuate the mixing chamber
you may need to run the mixing agitator
for a short time.
Î Close the mix chamber access door.
Restore power by closing the main dis-
connect switch.
Î Now you can manually run the mixer for
a short time (see 7.7.1 checking func-
tions in manual mode) to lower the mate-
rial level
Î If applicable, open the discharge slide
gate at the bottom of the mix chamber.
Î Open the mix chamber access door. The
safety unlock switch will prevent opera-
tion of the mixer with the door open.