TrueBlend™ Operation
Edition: February 2008 83
7.10.3 Setting Mixing time
The mixing time shows how long a batch is mixed after discharge from the mixer.
The factory setting is 10 to 15 seconds, depending on model.
Î Press the input field beside "Mix. time"
and input the desired duration in sec-
onds with the keypad.
Î Confirm the value with
.
7.10.4 Setting the Interval time
The interval time shows the time for which the mixer will “jog” several rotations to
ensure that the mixing blades do not stop in front of the sensor and thus generate
a "FULL" message. The factory setting is 30 seconds.
Î Press the input field beside "Interval
(s)" and input the desired duration in
seconds with the keypad.
Î Confirm the value with
.
7.10.5 Setting Damping
The following settings are available for im-
pact and vibration damping:
Î Select values < 2 to increase the sensi-
tivity of the scales.
Î Select values > 2 to reduce the sensi-
tivity of the scales and to reduce alarm
messages.
The factory setting for damping is "2".