User guide

TrueBlend Operation
Edition: February 2008 77
7.8.3 Typical dispense cycle based (7.8.2) settings
1st Step: regrind is metered
regrind 20% of total weight = 200 g
2nd Step: Natural material is calculated
as 100% of the balance of batch = 686 g
(automatically calculated/metered)
3rd Step: additive natural is metered
(Color) 2% of N = 13.7 g
(automatically calculated/metered)
4th Step: additive batch is metered
10% of total weight = 100 g
(automatically calculated/metered)
The controller must be set to match this sequence.
The percentage of natural material is automatically calculated by the controller.
[Sum of Natural(s) material = 100 %].
The percentages of the additive naturals are always based on the natural(s)
material.
The percentages of the additive batch are always based on the entire batch and
therefore are metered last.