User guide

Operation
TrueBlend
66 Edition: February 2008
7.7.4 Input TrueBlend name
Î In the "Overview" screen press the
TrueBlend icon.
The "TrueBlend Status" screen opens.
Î Press
.
The "Settings" screen appears.
Î Press
to open the "TrueBlend
Model/Name" screen.
The "TrueBlend Model/Name" screen ap-
pears.
Î Assign a name to the unit with alpha-
numeric keypad to give it a unique
identification.
Î Confirm with
.
Explanations of the “minimum retry
limit (%)” and “the maximum limit
batchweight (%).
Once a position has fed the setting (95%
or greater) the control will move on to the
next setting. If the blender does not reach
the setting within a prescribed number of
retries, it then evaluates whether it has
reached 50% of the target. If the blender
has not reached 50 % of the target the
blender will alarm on “Low Material,” and
continue to retry indefinitely until it
reaches the target weight.
The minimum retry limit (95) can be set
from 95 to 100.
NOTE
Increasing the minimum retry limit will decrease the average blender
throughput rate. A larger number of retries add up to more time to make a
batch. However, somewhat better accuracy can be achieved with the higher
number.