User guide
TrueBlend™ Operation
Edition: February 2008 61
Zero calibration
Î Press
.
"0" is displayed for "Actual Weight".
Full calibration
(for service users only!) (Level 3)
Î Press
to open the "Full Cali-
bration" screen.
Before the "Full Calibration" screen ap-
pears, you will be reminded that a full cali-
bration cannot be interrupted:
Î Press "Continue" if you want to pro-
ceed with the full calibration.
or
Î Press "Abort" to stop the full calibra-
tion.
Î Make sure that the weigh bin is empty
of material.
Î Press “Enter” to confirm.
A reference weight of 1250 g is assumed
as the factory setting for a TrueBlend 100
series blender or 750 g for a TrueBlend
045 series model.