3 Enter the default flow rates into the blender control on the dosing rate
screen.
4 Select the proper default settling times for the different valve
configurations from the following table:
Table from Product group
Example: Blender XYZ
Component 1 – 3” X 6” valve – 1.5 s
Component 2 – 3” X 6” valve – 1.5 s
Component 3 – 2” X 3” valve – 1.5s
Component 4 – 2” X 3” valve – 1.5 s
Component 5 – 2” i.d. feeder – 5 s
Component 6 – 1” i.d. feeder – 10 s
5 Enter the default settling times into the blender control on the settling times
screen.
6 Run a material calibration (see section 7.7.2) for each of the components.
7 Run the blender, making sure that all materials are present in sufficient
quantities for correct operation. While running, the blender control will
automatically adjust the dosing rate for optimum operation.