TrueBlend™ Maintenance and Repair
Edition: February 2008 129
9.6.1.1 Calibrate/adjust a sensor with material present
1
Press the button and keep
it pressed (5...10s).
The green LED flashes
slowly (approx. 1 Hz).
After approx. 5s it flashes
faster (approx 2 Hz)
(=unit is in the
programming mode).
2
Now release the button.
The yellow and green
LED’s are lit
(=unit is set and is in
the operating mode).
For most applications setting the sensor with the vessel empty is sufficient. You
can, if you wish, make additional adjustments with material present in the bin.
Making a full adjustment (material present) does not change the empty
adjustment. This type of adjustment may need to be completed for low bulk
density materials.
With material present, press and hold the pushbutton adjustment with a pen or a
small screwdriver for more than 5 seconds, but less than 10 seconds. For the first
5 seconds the green LED will flash slowly (approx. 1 Hz or 1 flash per second)
after approx 5 seconds then it will begin to flash faster (approx. 2 Hz or 2 flashes
per second). Release the pushbutton as soon as the green LED begins to flash
faster (approx. 2 Hz – or 2 flashes per second.
NOTE
The yellow and green LED’s will be lit – this means the unit is set and is in
operating mode.