User guide
TrueBlend™
Alarm Messages and
Troubleshooting
Edition: February 2008 119
8.6 Diagnostic Overview Screens
(for service users only!) (Level 3)
Access the “Settings” screen from the
Blender “Overview” screen. This screen
gives more detail to the individual material
dispenses making up a particular batch,
both target and actual percentages, as well
as, the running cumulative weight.
This screen shows the information used by
the blender for each batch.
Six materials are listed regardless how
many hoppers the blender has.
The open state of each component’s valve
is indicated by the presence of an icon
between the component number and the
material type.
%T = Percent Target
%A = Percent Actual
The start(ing) weight and the stop weight
are listed so you can subtract the two values
to get the weight of each component. This
data is useful to properly adjust settling
times and evaluate weigh bin fluctuations
due to electrical and mechanical problems.
The dosing rate in grams/seconds is also
listed for each component.