User guide
5-4 l Maintenance
Checking the Dewpoint (continued)
5 Turn on the portable instrument, and ensure there is positive airflow through
the sensor.
6 Monitor the readout and allow ample time for it to stabilize before
disconnecting the portable instrument. Some dewpoint monitors require a
substantial amount of time for residual moisture to be purged from the sensor.
7 In the event the dewpoint is not satisfactory, refer to the Troubleshooting
section of the manual, under Process Dewpoint alarm for DC2.
8 Stop the dryer, and allow it to cool down. Then disconnect your portable
instrument and replace any pipe plugs that may have been removed.
9 Close or replace the side panel.
1/8 inch NPT Hole Plug










