User guide
This screen shows the measured current on
each leg of the 3-phase power going to the
regeneration heater. The Regeneration
Current Monitor option (see screen 75,
page 4-26, also see note on this page) for
this to appear.
This screen shows the calculated total
power for the dryer. The calculation
includes the measured current for the
regeneration heaters, the control voltage
set for the dryer, and pre-determined
power consumption values for the blowers
and the control. The Current Monitor
option (see screen 75, page 4-26, also see
note on this page) for this to appear.
This screen displays the average dewpoint
over the last hour of run time.
This screen shows the actual temperature
measured at the regeneration outlet of the
desiccant wheel manifold.
Screen
SCREEN 22 (Current Monitor
Option)
SCREEN 23 (Current Monitor
Option)
SCREEN 24 Dewpoint Control
and Dewpoint Monitor
SCREEN 29 (Regeneration Outlet
Temperature)
Function
Operation l 4-15
4
Operation
Control Function Descriptions(continued)
REGEN CURRENTS
84.3 A 84.2 A 84.3 A
TOTAL POWER
82 KWH
DEWPOINT CONTROL
AVG -55°F
REGEN OUTLET TEMP
ACT 280
NOTE: Additional components
required for installation.
✐
NOTE: Additional components
required for installation.
✐
NOTE: Screens labeled 75 in
the display screen flow chart
on page 4-9 are various
option installation screens.
✐