User guide
Screen
SCREEN 1
SCREEN 2
SCREEN 4
SCREEN 5
Function
Once power is turned on, this screen is
displayed for 3 seconds. It shows
CONAIR and the dryer type on the first
line, and the control program version and
display program version on the second
line.
Once power is turned on and screen 1 is
displayed for 3 seconds, this screen is
displayed for another 3 seconds. It shows
the day of the week on the first line and
the date and time on the second line. If
this information is not correct, it can be
changed under the SETUP, DISP, DATE
TIME screen 73, page 4-25.
Shows the regeneration air setpoint and
actual temperature. The setpoint can be
changed with the correct password.
NOTE: Lowering the regeneration setpoint
decreases the capacity of the dryer and
normally is not recommended. Use the
dewpoint control function instead.
Shows the actual return air temperature
measured at the inlet to the process
blower. (The return air temperature on
W1600-5000 dryers is measured at the
inlet to the desiccant wheel. W1600-5000
dryers designed prior to August 2007, the
return air temperature is measured at the
inlet to the process blower.)
If the optional aftercooler/intercooler flow
control is installed, a setpoint will be dis-
played on this screen as well. The set-
point can be changed with the correct
password.
CONAIR D100
CV2.21.00 DV2.21.00
MONDAY
07/22/03 07:59 AM
Control Function Descriptions
4
Operation
NOTE: The supervisory
password is required to
change certain parameters.
More detail about the
password can be found
under screen 85, page 4-29.
✐
REGENERATION TEMP
ACT 350°F SET 350°F
RETURN AIR TEMP
ACT 100°F SET 100°F
✐
Operation l 4-11