Installation
Installation l 3-17
Connecting the Aftercooler and
Optional Precooler (W600 - 1000)
The aftercooler and/or optional precooler require a source of city, tower, or chiller
water and a discharge or return line. You can use water at temperatures of 45 to
85°F {7 to 29°C}. But the water flow should be at least 3 gal/min {11.4
liters/min}.
1 Connect the water supply line to
the aftercooler or precooler inlet.
If a manual shut off valve is used,
it should be mounted on the inlet
line.
2 Connect the water discharge or
return line with the pressure
relief valve to the aftercooler or
precooler outlet. Use the bracket
supplied to secure the pressure
relief valve to the back of the
dryer.
IMPORTANT: Turn the water off when the dryer is not in use to prevent
condensation.
Aftercooler Inlet
Aftercooler Outlet
✒
TIP: Make the water supply and dis-
charge / return connections with
flexible hoses at least 24 in.
(61 cm) long. This allows you to
easily remove the aftercooler
assembly for cleaning.
✒
TIP: If an optional flow control is
also being installed with the after-
cooler, the manual shut off valve
should be installed on the inlet line
for the flow control.
NOTE: Models W600-1000
dryer aftercooler and dry air
delivery configuration shown.
Location on larger models
are different. Refer to the
labeling on your dryer.
✐