User guide
3
Installation
Installation l 3-9
Opening the Dryer Doors
(W1600 - 5000)
Carousel Plus W Series 1600-5000 Dryers designed after August 2007 will have
locking side panel door bolts.
To unlock the side panel door bolts:
1 Rotate the two (2) locking door bolts on the dryer door counterclockwise
with a regular screw driver.
2 Close the dryer doors and rotate the two (2) locking door bolts clockwise
to resecure the dryer doors.
Checking for Proper Air Flow
This procedure is needed on W600-5000 models if the phase detection option was
not ordered with the dryer.
CAUTION: If the air flow direction is incorrect due to improper phase connection,
material from the hopper can be pulled back into the dryer, causing permanent
damage to this equipment.
1 Turn on the main power to the dryer. Make sure the dryer’s disconnect dial
is in the ON position. This powers up the control and the display lights will
illuminate.
2 Press the START button then the STOP button.
1
2
3
4
5
6
7
8
9
Clear
0
Enter
Adjust Setpoint
Acknowledge
Alarm
Start
Stop
Select
Category
Menu
Scroll List
Prev
Next
Auto Start
Dewpoint Control
Process Blower Regen. Blower
Regen. Heater
1000
3
3
Start
Stop
IMPORTANT: This procedure must be performed before the dryer’s air hoses are
connected to the hopper or before loading material into the hopper.
(continued)
Dryer Door
Locking Bolts (2)
(W1600-5000)