Specifications: Carousel Plus W
Series Dehumidifying Dryers
C
A
B
TPDS019-0311-REV
MODELS W600
*
W800
*
W1000
*
W1600
*
††
W2400
*
††
W3200
*
††
W5000
*
††
Performance characteristics (with full hopper)
Drying temperature All models 100 - 375
°
F {38 - 191
°
C} with options
Dewpoint All models -40
°
F {-40
°
C}
Dimensions inches {cm}
A - Height 92.6 {235.2} 95.5 {242.6} 102.8 {261.1}
B - Width 43.3 {109.9} 48.3 {122.7} 48.9 {124.2}
C - Depth 57.6 {146.3} 86.2 {218.9} 112.0 {284.5}
Outlet/inlet hose diameter 8 {20.3} 12 {30.5} 12 {30.5}
Approximate weight lbs {kg}
Installed 1300 {590} 1300 {590} 1400 {636} 1600 {726} 1600 {726} 2000 {907} 2000 {907}
Shipping 1495 {678} 1515 {687} 1515 {687} 2100 {953} 2620 {1188} 3385 {1535} 3385 {1535}
Voltage - Total amps
400 V/3 phase/50 Hz
37.2 37.2 37.5 64.7 73.7 122.3 128.0
460 V/3 phase/60 Hz 32.0 32.0 32.2 56.3 63.1 106.6 111.0
575 V/3 phase/60 Hz 25.6 25.6 25.7 45.0 50.5 85.3 89.1
Water requirements {for aftercooler/intercooler or optional precooler}
§
Recommended temperature
**
45
°
- 85
°
F {7- 29}
Water flow gal./min. {liters/min.} 6-25 {22.7-94.6} 12-40 {45.4-151.4} 15-50 {56.8-189.3}
Water connections NPT 1 1/2 in. NPT
SPECIFICATION NOTES:
* Dryers W600-W5000 are central dryers and do not have process heaters. Hopper Temperature Controllers (HTC’s) or ResinWorks systems are used at the
hopper for heating the process air. See the Hopper Temperature Controller (HTC) specification sheet for additional information.
Dryers running at 50 Hz will have 17% less airflow, and a 17% reduction in material throughput.
Total kW listed at a regeneration temperature of 350°F {177°C}.
§ When drying below 150 °F {66°C} a precooler is required. When drying above 180°F {82°C} an aftercooler/intercooler and insulated drying hose is
required.
** Temperatures above or below the recommended levels may affect dryer performance. Tower, chiller or municipal water sources can be used.
††
Models W1600-5000 do not have casters.
Specifications may change without notice. Consult a Conair representative for the most current information
.