User guide

Appendix l C-2
Cleaning the Volatile Trap on the
Demister
(W1600 - 5000)
1 Stop the dryer and lockout the main power.
2 Remove the thumbscrews then remove the volatile demister carriage and
demister from its housing.
3 Remove the demister from the demister carriage by pushing it out towards the
right side of the carriage.
4 Clean the assembly using a mild soap and water. Let the assembly dry
thoroughly before installation.
NOTE: In cases of heavy volatiles, steam cleaning or the use of solvents, such as acetone,
may be necessary. Be sure to test a small area with the solvent you have selected to be sure
there is no adverse reaction.
5 Insert the demister carefully back into the demister carriage and then replace
the entire assembly back into the demister housing.
6 Inspect the condition of the gasket. If it is damaged, replace the gasket.
7 Secure the cover in place using the original thumbscrews.